LED Iron Shell Mini Small Line Interactive Ups 1500VA 220V For Home Router Computer
Problem | Probable Cause | Solution |
No LED/LCD display on the front panel. | Low battery. | Charge the UPS at least 6 hours. |
Battery fault. | Replace the battery with the same type of battery. | |
The UPS is not turned on. | Press the switch again to turn on the UPS. | |
Alarm continuously sounds when the mains is normal. | The UPS is overload. | Remove some loads first. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs. |
When power fails, backup time is shorten. | The UPS is overload. | Remove some critical load. |
Battery voltage is too low. | Charge the UPS at least 6 hours. | |
Battery defect. It might be due to high temperature operation environment, or improper operation to battery. | Replace the battery with the same type of battery. | |
The mains is normal but LED/LCD is flashing.
| Power cord is loose. | Reconnect the power cord properly. |
Model | 1500 | |||
CAPACITY | 1500VA/ 900W | |||
INPUT | ||||
Voltage | 220 / 230 VAC | |||
Voltage Range | 162-268 VAC / 170-280 VAC | |||
OUTPUT | ||||
Voltage Regulation | -0.1 | |||
Transfer Time | Typical 2-6 ms, 10 ms max. | |||
Waveform | Simulated Sine Wave | |||
BATTERY | ||||
Type & Number | 12 V/9 AH x2 | |||
Charging Time | 6 hours recover to 90% capacity | |||
PHYSICAL | ||||
Dimension (DxWxH mm) | 370x 135 x 165 | |||
Net Weight (kgs) | 10.5 | |||
ENVIRONMENT | ||||
Humidity | 0-90 % RH @ 0-40℃ (non-condensing) | |||
Noise Level | Less than 40 dB |