Add to Cart
Design For Industrial Application High Start Torque 380v 3.7kw Three Phase Variable Frequency Drive
Product Description
The SVD-P series AC drive is a general-purpose high-performance current vector control AC drive. It is an upgrade product based on SVD-E and can implement the control of asynchronous motor and permanent magnet synchronous motor (PMSM). It increases the user programmable function, background monitoring software and communication bus function, and supports multi-kind PG cards. It is used to drive various automation production equipment involving textile, paper-making, wiredrawing, machine tool, packing, food, fan and pump.
Housing types for different voltage and power classes
Voltage & Power Class | Housing Type |
Single-phase 220 V | |
0.4–2.2 kW | Plastic housing |
Three-phase 220 V | |
0.4–7.5 kW | Plastic housing |
11–75 kW | Sheet metal housing |
Three-phase 380 V | |
0.75–15 kW | Plastic housing |
18.5–400 kW | Sheet metal housing |
Three-phase 480 V | |
0.75–15 kW | Plastic housing |
18.5–400 kW | Sheet metal housing |
Three-phase 690 V | |
55–500 kW | 55–500 kW |
Technical specifications of the SVD-P
Item | Specifications | |
Individualized functions | Multi-motor switchover | Four motors can be switched over via four groups of motor parameters. |
Multiple communication protocols |
It supports communication via Modbus-RTU, PROFIBUS- DP, CANlink and CANopen. | |
Motor overheat protection | The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection. | |
Multiple encoder types | It supports various encoders such as differential encoder, open-collector encoder, resolver, UVW encoder, and SIN/ COS encoder. | |
User programmable function | The optional programming card helps you to realize secondary development. Its programming environment is compatible with that of the PLC of Soyanpower. | |
Advanced background software | It supports the operation of AC drive parameters and virtual oscillograph function, via which the state inside the AC drive is monitored. | |
RUN |
Running command source | • Operation panel • Control terminals • Serial communication port You can perform switchover between these sources in various ways. |
Frequency source | There are a total of 10 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. You can perform switchover between these sources in various ways. | |
Auxiliary frequency source | There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis. | |
Input terminal | Standard: 5 digital input (DI) terminals, one of which supports up to 100 kHz high-speed pulse input 2 analog input (AI) terminals, one of which only supports 0– 10 V voltage input and the other supports 0–10 V voltage input or 4–20 mA current input Expanding capacity: 5 DI terminals 1 AI terminal that supports -10–10 V voltage input and also supports PT100PT1000 |